标准源通讯协议之直流模块举例

2020-01-0613:25:30 评论 411 views

设置直流电压100V

//数据域:
//DATA1: 0x34-0x33=0x01 表示设置电压值
//DATA2: 0x64-0x33=0x31 "1"
//DATA3: 0x63-0x33=0x30 "0"
//DATA4: 0x63-0x33=0x30 "0"
//DATA5: 0x33-0x33=0x00 0
//DATA6: 0x33-0x33=0x00 0
//DATA7: 0x33-0x33=0x00 0
//DATA8: 0x33-0x33=0x00 0
//DATA9: 0x33-0x33=0x00 0
68 1B 09 34 64 63 63 33 33 33 33 33 E9 16

设置直流电流5A

//数据域:
//DATA1: 0x35-0x33=0x02 表示设置电流值
//DATA2: 0x68-0x33=0x35 "5"
//DATA3: 0x61-0x33=0x2E 0
//DATA4: 0x65-0x33=0x32 0
//DATA5: 0x66-0x33=0x33 0
//DATA6: 0x67-0x33=0x34 0
//DATA7: 0x68-0x33=0x35 0
//DATA8: 0x69-0x33=0x36 0
//DATA9: 0x33-0x33=0x00 0
68 1B 09 35 68 33 33 33 33 33 33 33 8E 16

设置直流电流1.23456A

//数据域:
//DATA1: 0x35-0x33=0x02 表示设置电流值
//DATA2: 0x64-0x33=0x31 "1"
//DATA3: 0x61-0x33=0x2E "."
//DATA4: 0x65-0x33=0x32 "2"
//DATA5: 0x66-0x33=0x33 "3"
//DATA6: 0x67-0x33=0x34 "4"
//DATA7: 0x68-0x33=0x35 "5"
//DATA8: 0x69-0x33=0x36 "6"
//DATA9: 0x33-0x33=0x00 0
68 1B 09 35 64 61 65 66 67 68 69 33 BC 16

U升降 DATA=0-降

//数据域:
//DATA1: 0x36-0x33=0x03 表示电压操作
//DATA2: 0x33-0x33=0x00 降电压
68 1B 02 36 33 EE 16
//数据域:
//DATA1: 0x36-0x33=0x03 表示电压操作
//DATA2: 0x34-0x33=0x01 升电压
68 1B 02 36 34 EF 16

I升降 DATA=0-降

//数据域:
//DATA1: 0x37-0x33=0x04 表示电流操作
//DATA2: 0x33-0x33=0x00 降电流
68 1B 02 37 33 EF 16
//数据域:
//DATA1: 0x37-0x33=0x04 表示电流操作
//DATA2: 0x34-0x33=0x01 升电流
68 1B 02 37 34 F0 16

查询电压电流数据

//数据域:
//DATA1: 0x38-0x33=0x05 表示查询电压电流数据
68 1B 01 38 BC 16

举例 返回值:

//数据域:
//DATA1: 0x38-0x33=0x05 表示查询电压电流数据的返回帧
//电压值: 0x421F554B 表示浮点数 39.83329 V
//DATA2: 0x7E-0x33=0x4B
//DATA3: 0x88-0x33=0x55
//DATA4: 0x52-0x33=0x1F
//DATA5: 0x75-0x33=0x42
//电流值: 0x00000000 表示浮点数 0.00000 A
//DATA6: 0x33-0x33=0x00 0
//DATA7: 0x33-0x33=0x00 0
//DATA8: 0x33-0x33=0x00 0
//DATA9: 0x33-0x33=0x00 0
68 9B 09 38 7E 88 52 75 33 33 33 33 DD 16

关于协议:

《三相通讯协议》自 v2.15 版本开始:
1、增加3.12 从站报警帧 的D7 D6;
2、增加3.25 直流操作;

发表评论